3. Configure the RabbitLink network parameters. This is done using the serial console
commands. Typing the command “show” results in a listing of the current network
addresses.
Please refer to Appendix E, “Serial Console Commands,” for a description of all the
commands. If a DHCP server was not used, the following serial console commands are
required:
set ip x.x.x.x // factory default is 10.10.1.100
set gateway x.x.x.x // factory default is 10.10.1.1
set netmask x.x.x.x // factory default is 255.255.255.0
An alternative for setting the required network addresses is to change the default values
in the RabbitLink firmware, download.c.